dIX30C
Controllers Bucking

Head control unit for the bucking systems Dasa Wireless 1 and Dasa Wired 7

About dIX30C (1650-00)

Head control unit for the bucking systems Dasa Wireless 1 and Dasa Wired 7. The unit is responsible for handling inputs, outputs, control logic and bucking calculations. The controller also collects and sends data to the operator unit via an ethernet interface. The small installation footprint and high number of configurable inputs/outputs with gold-plated pins enables superior durability and uptime.

Get a quote You will hear from us soon

Compact
Robust
Designed for harvester head environment
Designed to reduce system cost
Deutsch connectors
Gold plated pins
Can control Danfoss valves
Dedicated GND and power supply pins for sensor inputs.
Improves fault detection and makes it easier to preassembly sensor cabling

General:
Weight: 1.5 kg (3.3 lbs)
Ambient temperature: operating– 40 to + 70 °C (–40 to 158 °F) storage– 40 to + 85 °C (–40 to 185 °F)
Protection class: IP67 (under the condition that all unused connectors are plugged)
Supply voltage: 10 – 30 V DC
Power consumption: <300 mA (24 V DC)
Size: 135 × 195 × 46.5 mm (5.31" × 7.68" × 1.83")
Chassis construction: Aluminum
Connectors: 3 pcs Deutsch DRC 1 pc Deutsch DT 

Outputs, PWM:
Max number of outputs: 18
Output current range: 0 – 3000 mA (1 mA resolution)

Danfoss/Digital outputs:
Max number of outputs: 12
Output voltage range: 5 – 95% of system voltage, alt. voltage output
Output current max: 5 mA/output

Inputs:
Max number of inputs: 12 (18)
Max number of voltage inputs: 8 (10) Analog/Digital
Max number of current inputs: 6 Analog
Max number of frequency inputs: 6
Max number of 2-channel pulse sensors: 6
Max number of enumerators: 6
Max number of digital inputs: 12 (18)
Voltage inputs0 – 30 V,0 – 10 V, 0 – 5 V, 
Current inputs: 4 – 20 mA
Digital inputs, pulse sensor inputs, switch level: 3.5 V